Enphase Solar Microinverters

Following are some of the products we deals with..

IQ 7 and IQ 7+ Microinverters

Features

The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years.


VIEW BROCHURE

    Easy to Install
  •  Lightweight and simple
  •  Faster installation with improved, lighter two-wire cabling
  •  Built-in rapid shutdown compliant (NEC 2014 & 2017)
    Productive and Reliable
  •  Optimized for high powered 60-cell and 72-cell* modules
  •  More than a million hours of testing
  •  Class II double-insulated enclosure
  •  UL listed
    Smart Grid Ready
  •  Complies with advanced grid support, voltage and frequency ride-through requirements
  •  Remotely updates to respond to changing grid requirements
  •  Configurable for varying grid profiles
  •  Meets CA Rule 21 (UL 1741-SA)
  • * The IQ 7+ Micro is required to support 72-cell modules.
Model Name IQ 7 and IQ 7+ Microinverters
INPUT DATA (DC) IQ7-60-2-US IQ7PLUS-72-2-US
Commonly used module pairings¹ 235 W - 350 W + 235 W - 440 W +
Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules
Maximum input DC voltage 48 V 60 V
Peak power tracking voltage 27 V - 37 V 27 V - 45 V
Operating range 16 V - 48 V 16 V - 60 V
Min/Max start voltage 22 V / 48 V 22 V / 60 V
Max DC short circuit current (module Isc) 15 A 15 A
Overvoltage class DC port II II
DC port backfeed current 0 A 0 A
PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit
OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter
Peak output power 250 VA 295 VA
Maximum continuous output power 240 VA 290 VA
Nominal (L-L) voltage/range² 240 V / 211-264 V 208 V / 183-229 V 240 V / 211-264 V 208 V / 183-229 V
Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V)
Nominal frequency 60 Hz 60 Hz
Extended frequency range 47 - 68 Hz 47 - 68 Hz
AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms
Maximum units per 20 A (L-L) branch circuit³ 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC)
Overvoltage class AC port III III
AC port backfeed current 18 mA 18 mA
Power factor setting 1.0 1.0
Power factor (adjustable) 0.85 leading ... 0.85 lagging 0.85 leading ... 0.85 lagging
EFFICIENCY @240 V @208 V @240 V @208 V
Peak efficiency 97.6 % 97.6 % 97.5 % 97.3 %
CEC weighted efficiency 97.0 % 97.0 % 97.0 % 97.0 %
MECHANICAL DATA
Ambient temperature range -40ºC to +65ºC
Relative humidity range 4% to 100% (condensing)
Peakefficiency -40ºC to +65ºC
Connector type MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter)
Dimensions (HxWxD) 40jkhkjC
212 mm x 175 mm x 30.2 mm (without bracket) 40jkhkjC
Weight 1.08 kg (2.38 lbs)
Cooling Natural convection - No fans
Approved for wet locations Yes
Pollution degree PD3
Enclosure Class II double-insulated, corrosion resistant polymeric enclosure
Environmental category / UV exposure rating NEMA Type 6 / outdoor
FEATURES
Communication Power Line Communication (PLC
Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy.
Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690.
Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions